Allyl chloride gas sensor – Flameproof LEL detector, ATEX, Zone 1, 2

Allyl Chloride is highly flammable (with LEL as 3.0% v/v), water insoluble liquid. Our Smart S series detector monitor LEL concentration of Allyl Chloride gas in ambient air or in ducts. It is flameproof or explosion proof sensor transmitter with ATEX and safety integrity level SIL 2 certified for hazardous area Zone 1, 2 installation. It is ideal for installation in chemical manufacturing, pesticides, pharmaceuticals, refinery, manufacturing units and so on

It is available with LCD Display, on-board relay contacts, flashing alarm LEDs, auto diagnostic watch dog, non-intrusive calibration, with industry standard linear analog output.

Description

Allyl Chloride gas LEL Monitor – flameproof sensor transmitter with ATEX, SIL 2 for hazardous area Zone 1, 2

online, continuous detection and monitoring of LEL or flammable level of Allyl Chloride gas or vapour in ambient air or ducts, flameproof / explosion proof certified Zone 1, 2 – ATEX, SIL 2, with / without display, contact relays, flashing alarm LEDs, RS485 serial interface
pdf download icon
Model: S2XX7

Allyl Chloride is clear colorless liquid with an unpleasant pungent odor, It is highly flammable and insoluble in water. It presents a serious fire and explosion hazard when exposed to heat, flame or oxidizing agents. Polymerizes violently and exothermically with Lewis acids or metals. Attempts to alkylate benzene or toluene using Allyl chloride in the presence of ethylaluminum chlorides have led to explosions.

Flammable Limits: Lower (LEL): 3.30% v/v     Upper (UEL): 11.2% v/v.

SMART S series Allyl Chloride gas or vapour sensor transmitter is high performance, rugged, industrial grade, flameproof or explosion proof instrument for LEL concentration detection. The instrument can be installed for flammability level or LEL detection of Allyl Chloride gas or leakage in all industrial and commercial area eg. chemical plant, pharmaceuticals, water cleansing agent, pesticides manufacturing, solvent manufacturing unit, warehouse etc

The detector can be installed at walls, surfaces or in ducts for monitoring in gas or air sample. It is ATEX EEx’d’ certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.
Explosion proof or flameproof gas sensor transmitter - ATEX, Zone 1, 2 for all toxic, flammable gas, oxygen
The sensor transmitter offers linear, proportional analog output in industry standard current signals, over measuring range of 0 ~ 100% LEL (lower explosive limit). The detector works on highly sensitive catalytic bead based pellistor sensor cell, with low response time. It has unique feature of auto diagnostic watch dog with zero-point tracking feature. Due to its 10-bit microprocessor based control unit, it offers high accuracy over long term. The detector is also equipped with sintered filter with flashback arrestor for enhanced safety.

Allyl chloride sensor - LEL detector for Zone 1 explosion proof hazardous area, SIL 2, LCD Display, potential free relays
Allyl chloride sensor – LEL detector for Zone 1 explosion proof hazardous area, SIL 2, LCD Display, potential free relays

It also offers optional features like inbuilt LCD display, flashing alarm LEDs, on-board potential free relay contacts (24VDC @ 1 A), RS485 serial interface with Modbus RTU communication.

 

Key Features:

  • Catalytic bead based Pellistor sensor cell with low flash energy
  • 10-bit microprocessor control unit
  • Non-intrusive one-man calibration via hall effect switches
  • ATEX certified explosion proof / flameproof, suitable for Zone 1, 2 gas explosion installation
  • Linear, proportional analog industry standard current output
  • Continuous system self-diagnosis with watch dog
  • Flashback arrestor with sintered filter
  • Auto Zero-point tracking to zero-point compensation
  • SIL 2 HW TUV certified
  • RS485 serial interface with Modbus RTU communication (optional)
  • 1 or 3 relay output module (optional)
  • System and alarm LED indicators (optional)
  • Modbus RTU communication over RS485 serial interface

 

Allyl Chloride LEL monitor - analog transmitter, online, wall mount, Zone 1 ATEX for explosion proof hazardous area
Allyl Chloride LEL monitor – analog transmitter, online, wall mount, Zone 1 ATEX for explosion proof hazardous area

Technical Specifications:

  • Measuring Parameters: LEL or flammable concentration of Allyl Chloride gas (3.3% v/v)
  • Sensor Technology: Catalytic bead based pellistor sensor cell
  • Measuring range: 0 ~ 100% LEL
  • Response time (t90): < 30 sec
  • Control unit: 10-bit microprocessor based
  • Warm up time: < 5 mins
  • Auto zero-point tracking for drift compensation
  • Power supply: 24V DC
  • Ingress protection: IP65
  • Enclosure: Stainless steel (for sensor cell), anti-static epoxy coated metal alloy (for transmitter)
  • Output: linear, proportional 4-20mA
  • Mounting: wall, duct, pipeline
  • Safety integrity level: SIL 2
  • ATEX marking:
    • CE 722 Ex II 2G EEx d IIC T6
    • CE 722 Ex II 3G EEx nA IIC T6
  • Optional: LCD Display, alarm LEDs, potential free relay contacts
  • Hazardous area: Zone 1, 2

 

Application:

  • Chemical manufacturing plants
  • Water clarification and sewage sludge flocculation
  • Pharmaceuticals and pesticide manufacturing
  • Resin manufacturing